Double Hung Basement Egress Window
The window is designed to fit into a standard basement window space making it a good diy project.
Double hung basement egress window. That means the entire window must be more than 48 inches high. This means that to meet egress window height requirements a bedroom window must be nearly 4 ft. These double pane vinyl compact single hung in swing egress windows are typically used in rooms when space to install a double hung egress window is limited or for basement egress applications. W 2500 series primed wood double hung window w natural interior and low e glass model z40049 307 01 307 01.
Even when it s fully open more than half of a double hung window s overall area is blocked by glass. Double hung egress windows feature two panes of glass and are normally designed so that both the top and bottom sash can be raised and lowered. Some double hung windows open from top to bottom but it is not as common. Get free shipping on qualified meets egress requirements double hung windows or buy online pick up in store today in the doors windows department.
Exceeds the 5 7 sq. Agron gas filled double paned insulated low e glass by guardian with a u value of 0 24. This height requirement takes it out of the running for most basement egress situations. Opening size required by code.
Redi exit compact series single hung in swing egress windows are designed to meet the irc code requirements of 5 7 square feet of clear area 20 minimum width and 24 minimum height as well as the current irc energy requirements. They also need to be relatively large to meet the minimum size requirement for egress windows needing a space 28 inches to 60 inches wide and 23 5 inches to 60 inches high. Again watch the maximum sill height. When the sill height of an egress window is located below grade common for egress windows provided for a basement a window well must be provided.
Single or double hung windows are minimally 3 0 wide by 4 8 high or 2 8 wide and 5 6 high. Slider windows are minimally 4 0 by 4 0. The area of a window well shall not be less than 9 square feet with a horizontal length width of no less than 36 inches. Anderson s double hung sizes.
Fiberglass screen to keep out bugs. If the ceiling of your basement is not several feet above ground level or you do not have window wells that are at least three feet deep you most likely cannot use double hung windows. Truck tool rental. Egress window well code requirements.
I ve seen a 2 6 wide by 5 0 high egress window but not all manufacturers make this window size. The basic idea is that because someone can only exit through what is.